LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Local/Remote
LRS=
LRS?
State
Unit MAC Address N/A
MAC?
Maximum
N/A
N/A
Operating Point
Arguments for
Command or
Query
1 byte
Command or Query.
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for Outdoor SSPA) in the form x,
where x=0, 1, 2, or 3::
0=Local
1=Serial
2=Ethernet
3=Serial+Ethernet (DEFAULT)
NOTE: You will always have LRS query access in any mode. The LRS command is available in all modes as a means
of acquiring control so as to limit changes from being made on multiple interfaces at the same time. Units without
a front panel (e.g., the LPOD) treat an entry of 0 as "reserved" and refuse the command by returning a mode
error. The HTTP Interface prohibits connections unless you set LRS to accept Ethernet remote control.
COMMAND EXAMPLE: <0001/LRS=3{CR}
17 bytes
Query only.
Returns the read-only MAC address of the unit, in hexadecimal format xx-xx-xx-xx-xx-xx
EXAMPLE: <0001/MAC?{CR}
>0001/MAC=00-06-B0-00-D2-A7{CR}{LF}
272 bytes
Query only.
Returns the maximum operating point of the unit along with its timestamp in the reply format:
MAXFET=sYYYC mmddyy hhmmss{CR}
MINFET=sYYYC mmddyy hhmmss{CR}
MAXPFT=sYYYC mmddyy hhmmss{CR}
MAXDTP=sYYYC mmddyy hhmmss{CR}
MAXHTS=sYYYC mmddyy hhmmss{CR}
MINHTS=sYYYC mmddyy hhmmss{CR}
MAXOST=sYYYC mmddyy hhmmss{CR}
MAXRFP=sZZ.ZZ mmddyy hhmmss{CR}
MINRFP=sZZ.ZZ mmddyy hhmmss{CR}
Where:
sYYYC is the temperature
sZZ.ZZ is the power
NOTE: Not all LPODs have outside temperature monitor. In which case MAXOST and MINOST report XXXXX XXXXXX XXXXXX
EXAMPLE: <0001/MOP?{CR}
>0001/mop={CR}
MAXFET=+000C 010208 180729{CR}
MINFET=+000C 010208 180729{CR}
MAXPFT=+000C 010208 180659{CR}
MAXDTP=+000C 010208 180729{CR}
MAXHTS=+050C 010208 180729{CR}
MINHTS=+050C 010208 180729{CR}
MAXOST=XXXXX XXXXXX XXXXXX{CR}
MINOST=XXXXX XXXXXX XXXXXX{CR}
MAXRFP=+00.00 010208 180659{CR}
MINRFP=+00.00 010208 180659{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–20
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
LRS=
LRS=x
LRS?
MAC=
MAC=xx-xx-xx-
xx-xx-xx
MOP=