LPOD-R Outdoor Amplifier / Block Up Converter
Ethernet Interface Operation
4.5.3 Config Pages
Use the Configuration pages to configure all operating parameters for the
LPOD-R. Click Amplifier or Utility to continue,
4.5.3.1 Config | Amplifier
Use this page to configure the communications, operations and alarms/faults
handling for the amplifier. Refresh the page to see the latest data.
Figure 4-9. Config | Amplifier Page
Amplifier
• Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in
0.25 dB steps.
• Fault Recovery – Use the drop-down list to select Automatic or Manual.
• User Mute – Use the drop-down list to select Enabled or Disabled.
Click Change Configuration to save any changes.
Low Forward Power Threshold (dBm)
Set the threshold value, in dBm, for the low forward power alarm/fault.
When the forward power monitor is set to Alarm or Fault instead of the factory
default of Mask, and the forward power drops below the specified value, the
alarm/fault occurs.
To disable the threshold, set this parameter to the default value of 00.00.
Click Change to save any changes.