Config | Redundancy - Comtech EF Data LPOD Series Installation And Operation Manual

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

4.5.3.4

Config | Redundancy

Appendix A. 1:1 REDUNDANCY
Redundancy
Click [Refresh] to see the latest page data.
Name
Enable Redundancy Switch
Mode
Online Status (read-only)
Force Online
Ethernet Interface Operation
Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Figure 4-14. 'Config | Redundancy' Page
Use the drop-down list to select the Switch Mode as follows:
Off disables redundancy
1:1 Red TX enables 1:1 redundancy with transmit switch control.
1:1 Red TX+RX enables 1:1 redundancy with transmit and receive
switch control.
Manual enables manual redundancy mode.
Click [Change] to save.
The active status for the unit displays Online or Offline.
Click [Force Online] to force a unit to go active (online).