Front Panel Indicators; Built-In Redundancy Controller; Table 1-2. Front Panel Indicators - Comtech EF Data KPA080 Installation And Operation Manual

Ku-band solid-state power amplifier
Table of Contents

Advertisement

Introduction
1.2.2

Front Panel Indicators

There are six LED indicator lights on the front panel which indicate the status of the
SSPA and provide summary fault information. Refer to Table 1-2 for description of the
LED lamps:
Stored Fault
Power Status
1.2.3

Built-in Redundancy Controller

Each SSPA has the ability to function as a 1+1 or 1+2 redundancy controller in the
backup mode. The optional redundancy configuration is implemented by attaching a
ganged Waveguide/coax transfer switch(es) to input and output connectors of the
amplifiers with a combination coaxial cable and Waveguide kit. When the backup SSPA
is commanded into the controller mode, it monitors the online SSPA(s) for faults. A
faulted online unit may be disconnected and replaced without affecting the online power
amplifier.
1-4

Table 1-2. Front Panel Indicators

LED
Lamp
Fault
Red
Red
Green
TX ON
Yellow
Online
Yellow
Remote
Yellow
KPA080 Ku-Band Solid-State Power Amplifier
Condition
Indicates that a fault condition exists when the LED light is
On.
Indicates that the fault has been logged and stored When the
LED light is On. The fault may, or may not, be active.
Indicates that power is applied to the SSPA when the LED
light is On.
Indicates that the transmit function of the SSPA is on when
the LED light is On. The indicator light reflects the actual
condition of the transmit function.
Indicates that the SSPA is operating on-line to transmit data.
Indicates that the SSPA is being operated in the remote
control mode where commands and data are transferred via
an EIA-485 (EIA-232 is optional) serial
communications link.