Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 149

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
LNB Current
LCW=
LCW?
Window
Retrieve next 5
N/A
LNA?
unread Stored
Alarms*
Low Power
LPT=
LPT?
forward Threshold
Arguments for
Command or
Query
2 bytes
Command or Query.
Sets or returns the alarm window in ±% of the calibrated LNB Current in the form xx, where:
xx=20 to 50, in increments of 1(%); set to 99 to disable (SEE NOTE).
Default value: 30
NOTE: A query return value of 99 indicates that the current window is disabled. This method is due to become
obsolete. Comtech recommends that you use the CWE command/query instead of specifying 99 here.
COMMAND EXAMPLE: <0001/LCW=30{CR} (sets the alarm window to ±30%)
145 bytes
Query only.
Returns the five oldest stored events in the alarm log, in the reply format:
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}
YYYYYYYYYY ZZ mmddyy hhmmss{CR}{LF}
Where:
YYYYYYYYYY is the fault description.
ZZ is the event type FT=Fault; OK=Clear; or IF=Information
mmddyy hhmmss=date / time stamp.
NOTE: If there are no events in the log the unit will reply with LNA*. All events that are read from the log are also
automatically removed from the log.
EXAMPLE: <0001/LNA?{CR}
>0001/LNA={CR}
LOG CLR IF 175503 052307{CR}
FAN #1 FT 175504 052307{CR}
OVR TMP FT 175504 052307{CR}
FAN #1 OK 175504 052307{CR}
IIC BUS FT 175504 052307{CR}{LF}
5 bytes
Command or Query.
Sets or returns the threshold for the low forward power alarm/fault in the form xx.xx:
Default value: 00.00
NOTES:
1)
If the forward power drops below the specified value, the alarm/fault will be indicated.
2)
Setting this parameter to 00.00 effectively disables the threshold.
COMMAND EXAMPLE: <0001/LPT=00.00{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–19
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
LCW=
LCW=xx
LCW?
LCW*
LNA=
LNA=YY..ss
LPT =
LPT=xx.x
LPT?
LPT *

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 2Lpod

Table of Contents