Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 156

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Retrieve
N/A
RMS?
Maintenance
Status
Arguments for
Command or
Query
213 bytes,
Query only.
alphanumeric
Returns maintenance status as per the following example:
<0001/RMS?{CR}
>0001/RMS={CR}
P24V1=024.1{CR} +24V power supply
P24V2=024.1{CR} +24V switch power supply
LNBVT=018.2{CR} +13/18V LNB power supply (SEE NOTE)
P13VT=013.4{CR} +13.5V power supply
P10V1=010.1{CR} +10V1 power supply
A10V1=010.1{CR} 10V1 on RF Module
A10V2=010.1{CR} 10V2 on RF Module (SEE NOTE)
P7V8T=007.8{CR} +7.8V power supply
P5V8T=005.8{CR} +5.8V power supply
P2V5T=002.5{CR} +2.5V power supply
P1V2T=001.2{CR} +1.2V power supply
N5V8T=-05.7{CR} -5.8V power supply
FANR1=100.0{CR} Fan 1 speed in percent
FANR2=100.0{CR} Fan 2 speed in percent (SEE NOTE)
BUCVT=008.3{CR} BUC tuning voltage (SEE NOTE)
FWPWR=+53.2{CR} Forward power in dBm
REFVT=001.8{CR} Reference osc. tuning voltage (SEE NOTE)
LNBCS=380.2{CR} LNB current supply in mA (SEE NOTE)
ATEMP=+40.0{CR} Heatsink temperature in Celsius
OTEMP=+25.0{CR}{LF} Outdoor temperature in Celsius (SEE NOTE)
NOTE: LNBVT, FANR2, A10V2, BUCVT, REFVT, LNBCS, and OTEMP appear if the appropriate options are installed;
otherwise, the values will report XXXX.
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–26
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
RMS=