LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Ethernet Interface Operation
This scrolling page provides graphs that show trends over time for the following
operating parameters:
• Amplifier Temperature
• Amplifier Output Power
• LNB Current
• Operating Status
• Rx Mute Status
• Online Status
• Minimum Fan Speed
Trending Graph Time Settings
Choose the time, date, and duration of the trending information displayed on the
graphs.
• Start Date (mm/dd/yy): Once a unit has been in operation for 24 hours
or more, use the drop-down list to select a date – up to a maximum of 28
days, including the present date – from which to compile data. If a unit
has not been in operation for 24 hours, only present will be available.
• Time: Once a unit has been in
operation for 24 hours or more,
use this drop-down list to select the time on the hour – 24 hours, from 12
am to 11 pm, are available. Note that, for the first 24 hours of operation
(or beyond if the time has accrued), if you select present as the Start
Date, then the Time drop-down list becomes unavailable for selection
and dims as shown here.
• Duration: Use the drop-down list to select the block of time in which data
is compiled for the graphs. Select 30 minutes, 1 hour, 2 hours, 4 hours, 6
hours, 8 hours, 12 hours, 24 hours, or 48 hours.
The LPOD stores the trending data to flash memory once per hour. If
you power down the unit before the data can be written to memory,
the last 60 minutes of data will be lost.
Click [Submit] to execute your settings choices.