Trap Version: Use the drop-down list to select the SNMP Trap Version as SNMPv1 or
SNMPv2.
For details pertaining to the remaining configuration parameters available on this page, see Section
6.3 SNMP INTERFACE.
Click [Submit SNMP] to save. If it is desired to revert back to the previously assigned SNMP
designations, click [Reset] instead.
4.5.4.3

Config (TRP1000-4450 Configuration) Pages

Select the Amplifier or Utility hyperlink to continue.
4.5.4.3.1
Config | Amplifier
Use this page to configure the communications, operations, and alarms/faults handling for the
amplifier.
To update the page to the current amplifier configuration: Click [Refresh].
Serial
Remote Address – Enter a valid physical remote address from 0001 to 9999.
Baud Rate – Use the drop-down list to select the operating baud rate as 2400, 4800, 9600,
19200, or 38400 baud
Data Bits - Parity - Stop Bits – Use the drop-down list to select the data bits, parity, andstop
bits as 8-N-1, 7-E-2, or 7-O-2. Default is 8-N-1.
Click [Save Changes] to save.
Ethernet-based Remote Product Management
TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Figure 4-5. Config | Amplifier Page
4–14
Revision 0
MN-TRP1000-OD