Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 159

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Switch Bias Tee
SBT=
SBT?
Set FSK Address
SFA=
SFA?
Summary Fault
N/A
SFS?
Status*
SNMP
SNA=
SNA?
Authentication
Trap Enable
SNMP Enable
SNM=
SNM?
Serial Number
N/A
SNO?
Set Physical
SPA=
SPA?
remote Address
Arguments for
Command or
Query
1 byte
Command or Query.
numeric
Sets or returns switching of the bias tee into the through state or into the off state, in the form x, where:
0=Off State (mute LNB) (DEFAULT)
1=Through State (unmute LNB)
NOTES:
1) The bias tee provides a means of muting the LNB. The SBT state will be controlled by the amplifier mute state
while running in redundancy mode, but while the unit is not in redundancy mode the bias tee may be set
independently of the amplifier mute state.
2) To send this command the unit must have the bias tee option installed; otherwise, a mode error will result. A
mode error will also result if this command is sent while the unit is running in redundancy mode.
COMMAND EXAMPLE: <0001/SBT=1{CR}
2 bytes,
Command or Query.
numeric
Sets or returns the FSK Address in the form xx, where:
xx=Address value from 01 (DEFAULT) to 15.
COMMAND EXAMPLE: <0001/SFA=01{CR}
1 byte
Query only.
Returns the summary fault state in the form x, where:
0=Not Faulted (SumFLT_COM J6 pin K is not connected to SumFLT_NC J6 pin M)
1=Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M)
EXAMPLE: <0001/SFS?{CR}
>0001/SFS=0{CR}{LF}
1 byte
Command or Query.
Sets or returns the SNMP Authentication Trap in the form x, where:
0=Disabled
1=Enabled
COMMAND EXAMPLE: <0001/SNA=0{CR}
1 byte
Command or Query.
Sets or returns SNMP in the form x, where:
0=Disabled
1=Enabled
COMMAND EXAMPLE: <0001/SNM=0{CR}
9 bytes
Query only.
Returns the unit's nine-digit serial number in the form xxxxxxxxx.
NOTE: This query is functionally identical to RSN.
EXAMPLE: <0001/SNO?{CR}
>0001/SNO=012345678{CR}{LF}
4 bytes
Command or Query.
Sets or returns the Physical Address in the form xxxx where:
xxxx=Address value from 0001 (DEFAULT) to 9999.
COMMAND EXAMPLE: <0001/SPA=0412{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–29
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
SBT=
SBT=x
SBT?
SBT*
SFA =
SFA=xx
SFA?
SFA*
SFS=
SFS=x
SNA=
SNA=x
SNA?
SNM=
SNM=x
SNM?
SNO=
SNO=xxxxxxxxx
SPA=
SPA=xxxx
SPA?
SPA*