Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 162

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Terminal Status
N/A
TSC?
Change
External
XRM=
XRM?
Reference Mute
Arguments for
Command or
Query
1 byte
Query only.
Indicates if there has been a change in the configuration since the last time the command was given, in the form
x, where:
0=No status change.
1=Status change has occurred.
NOTES:
1) A "status change" is defined as any time a parameter is changed, e.g., when a command is successfully
executed that changes a value. A status change also results when there is a fault condition.
2) A query does not set the status change flag. The status change flag is cleared after being read.
EXAMPLE: <0001/TSC?{CR}
>0001/TSC=0{CR}{LF}
1 byte
Command or Query.
numeric
Sets or returns the external reference mute state in the form x, where:
0=Disable
1=Enable (SEE NOTE)
NOTE: To enable this command, the internal reference oscillator option must be installed; otherwise, a mode
error will result. A hardware mute condition generated by the XRM mute is one of the conditions that can cause
the MUT command to return MUT=2. When enabled, the unit mutes when an external reference oscillator is not
detected.
EXAMPLE: <0001/XRM=1{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–32
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
TSC=
TSC=x
XRM=
XRM=x
XRM?