LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Introduction
Gain Min (Typical)
Input Power Supply Requirements
Max IF Input level (no damage)
Gain Adjust
Gain Flatness
Gain variation over temp
Input Return Loss
Output Return Loss
Noise Figure
RF Mute Isolation
AM/PM Conversion
Third-order Intermodulation Level
(2 tones, @ -3 dB Total Backoff from P1 dB
(-6 dBc SCL), Δ 1MHz)
Spurious Level
Group delay variation
Data Logging Parameters
70 (75 dB)
90-264 VAC, 47-63 Hz, Power Factor Corrected,
.96 (typical)
(48 VDC optional)
+10 dBm
20 dB in 0.25 dB steps
± 1.5 dB full band (optional ± 2.0 dB full band (-50°
to +55°C))
± 0.30 dB per 40 MHz (optional ± 0.50 dB per 40
MHz (-50° to +55°C)
±1.5 dB max, -40° to +55°C (optional ± 2.0 dB max (-
50° to +55°C))
15 dB
19.1 dB (1.25:1 VSWR)
10-15 dB typ, 20 dB max @ min attenuation, (8 dB
typ, 15 dB max PS2 configured as SSPA only)
-60 dBc min
2° typ, 3.5° max @ Rated P1dB
-30 dBc typ, -25 dBc Guaranteed
Harmonics
-50 dBc @ Prated – 3 dB
Carrier Related In
-60 dBc min @ P1dB
Band
Non-Carrier
-60 dBm max (Input Terminated)
Related In Band
LO Leakage
-25 dBm max
Linear
± 0.03 ns/MHz
Parabolic
±0 .003 ns/MHz
Ripple
± 1.0 ns pk-pk
Non-Volatile RAM: Capacity 30 days @ 90 minute
intervals. Includes:
RF Output Power
Mute Status
Heatsink Temperature
LNB Bias Current
1–11
2
MN-LPOD
Revision 14