LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Software Revision
N/A
SWR?
Set RTC Time
TIM=
TIM?
Temperature
N/A
TMP?
Retrieve Number
N/A
TNA?
of unread stored
Alarms*
Retrieve Number
N/A
TNE?
of Unread Stored
Events
Time Protocol
TPE=
TPE?
Enable
Time Protocol
TPS=
TPS?
Server
Arguments for
Command or
Query
34-37 bytes
Query only.
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
6 bytes
Command or Query.
Sets or returns the Real-Time-Clock time in the form hhmmss, where:
hh=hours, from 00 to 23;
mm=minutes, from 00 to 59,
ss=seconds, from 00 to 59
COMMAND EXAMPLE (time=23 hours, 12 minutes and 59 seconds since midnight – i.e., 11:12:59 PM):
<0001/TIM=231259{CR}
5 bytes
Query only.
Returns the temperature of the Heatsink in the form sxxxx, where:
s=sign byte, positive or negative (+ or –)
xxxx=temperature (including decimal point)
EXAMPLE: <0001/TMP?{CR}
<0001/TMP=+26.0{CR}{LF}
2 bytes
Query only.
Returns the number of stored events that remain unread in the alarm log in the form xx, where:
xx=number from 00 to 99.
NOTE: Although a maximum of 255 events may be stored in the alarm log, event tallies greater than 99 are
reported as 99.
EXAMPLE: <0001/TNA?{CR}
>0001/TNA=14{CR}{LF}
2 bytes,
Query Only.
numerical
Returns the number of stored events that remain unread in the events logs, in the form xx.
EXAMPLE: <1/TNE?{CR}
>0001/TNE=18{CR}{LF}
1 byte,
Command or Query.
numerical
Sets or returns Time Protocol in the form x, where:
0=Disable
1=Enable
COMMAND EXAMPLE: <0001/TPE=1{CR} (Enables Time protocol)
15 bytes,
Command or Query.
alphanumeric
Sets or returns the Time Server IP Address for the unit's Tx Ethernet management port, in the form
xxx.xxx.xxx.xxx.
Default value: 255.255.255.255
COMMAND EXAMPLE: <0001/TPS=192.168.001.005{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–31
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
SWR=
SWR=Boot:x.y.z
z Bulk1:x.y.zz
Bulk2:x.y.z
TIM =
TIM=xxxxxx
TIM?
TIM *
TMP=
TMP=sxxxx
TNA=
TNA=xx
TNE=
TNE=xx
TPE=
TPE=x
TPE?
TPS=
TPS=xx.xxx.xxx.
TPS?
xxx