LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Circuit
CID=
CID?
Identification
Calibrate LNB
CLC=
CLC?
Current
Concise
N/A
CMS?
Maintenance
Status
Arguments for
Command or
Query
48 bytes
Command or Query.
Sets or returns the user-defined label for the unit or station.
NOTE: The 48-character string is entered as one line, but it is read back from the unit as two 24-byte lines of
information.
Default Setting: ------CID MESSAGE-------
------------------------
COMMAND EXAMPLE: <0001/CID= Station #001--SSPA #01--{CR}
QUERY EXAMPLE: <0001/CID?{CR}
>0001/CID={CR}
Station #001{CR}
--SSPA #01--{CR}{LF}
none
Command or Query.
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.
Default value: 000.0
NOTES:
1) This command returns a mode error if the LNB current source output has not been enabled first (see LCS
command).
2) The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current
window setting (see LCW command).
3) The CLC query returns the value that was stored during the LNB current calibration.
COMMAND EXAMPLE: <1/CLC=xxx.x{CR} (where xxx.x is the calibrated LNB current value in mA)
QUERY EXAMPLE: <1/CLC?{CR}
>0001/CLC=xxx.x{CR}{LF}
95 bytes
Query only.
Returns the Maintenance status of the unit, response is semicolon-delimited, in the form
aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n; ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t
where:
aaa.a=P24V1
bbb.b=P24V2
ccc.c=LNBVT (SEE NOTE 2)
ddd.d=P13VT
eee.e=P10V1
fff.f=A10V1
ggg.g=A10V2 (SEE NOTE 2)
hhh.h=P7V8T
iii.i=P5V8T
jjj.j=P2V5T
kkk.k=P1V2T
lll.l=N5V8T
mmm.m=FANR1 (SEE NOTE 2)
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
>0001/CID={CR}{LF}
5–14
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
CID=
CID=x;...x
CID?
CID*
CLC=
CLC=xxx.x
CLC?
CLC*
CMS=
CMS=x....x