LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Retrieve Next 5
N/A
RNS?
unread stored
Statistics
Serial Number*
N/A
RSN?
Retrieve Utility
N/A
RUS?
Status
Remote Baud Rate SBR=
SBR?
Arguments for
Command or
Query
75 bytes
Query only.
Returns the oldest 5 unread stored statistics entries in the reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body, where:
Sub-body= ddmmyyhhmmssaaa.abbb.bccc.cdd.ddefghhh.hiii.i
ddmmyy=day/month/year
hhmmss=hour:minute:second
aaa.a=Operating Temperature (e.g., +40.0)
bbb.b=Amp Temperature (e.g., +40.0)
ccc.c=RF Power output
dd.dd=Attenuation Setting
e=Amp On/Off
f =Mute On/Off
g=Online/Offline Status
hhh.h=LNB Current (mA)
iii.i=BUC Tuning Voltage
NOTE: If there are less than 5 entries to be retrieved, the remaining positions are padded with zeros. If there are
no new entries, the response is RNS*.
9 bytes
Query only.
Returns the unit's nine-digit serial number in the form xxxxxxxxx.
EXAMPLE: <0001/RSN?{CR}
>0001/RSN=0123445678{CR}{LF}
23 bytes,
Query only.
alphanumeric
Returns the utility status of the unit.
EXAMPLE: <0001/RUS?{CR}
>0001/RUS={CR}
ADR=0001{CR}
BDR=9600{CR}
REF=087{CR}{LF} (REF displays only if a reference oscillator is installed)
4 bytes
Command or Query.
Sets or returns the remote baud rate in the form xxxx, where:
2400=2400 baud
4800=4800 baud
9600=9600 baud (DEFAULT)
19K2=19200 baud
38K4=38400 baud
NOTE: When changing baud rates remotely the response to the command will be returned using the same baud
rate as that used to send the command.
COMMAND EXAMPLE: <0001/SBR=19K2{CR}
QUERY EXAMPLE: <0001/SBR?{CR}
>0001/SBR=9600{CR}{LF}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–28
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
RNS=
RNS={CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body
RSN=
RSN=xxxxxxxxx
RUS=
RUS=x....x
SBR=
SBR=xxxx
SBR?
SBR*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 2Lpod