5-2-1

R6YXCH250, R6YXCH350, R6YXCH400

The following steps describe procedures and precautions when replacing the
harmonic drives of the R6YXCH250, R6YXCH350 and R6YXCH400.
For the bolt tightening torques in this work, refer to Table 5-2.
1. X-axis
1) Prepare the following tools and items.
• Harmonic grease 4B No.2
• Waste cloth (rag)
• Phillips-head screwdriver
• Hex wrench set
• Screw Lock (thread sealant)
• Ratchet handle
• Hexagonal socket set
• Extension bar
• Torque-limiting wrench
• Replacement parts (See table below.)
Parts name
Harmonic
O-ring
2) Turn off the controller.
3) Place a sign indicating that the robot is being inspected, to keep others from
operating the controller switch.
4) Enter the safeguard enclosure.
5) Remove the base (robot pedestal) front and rear covers.
Refer to "7 Removing the Robot Covers" in Chapter 4 for removing the
covers.
WARNING
WHEN YOU REMOVE THE X-AXIS ARM INSTALLATION BOLTS
(M3×40L, 8 PIECES) IN THE NEXT STEP, THE X-AXIS ARM MAY COME
OFF CAUSING A HAZARDOUS SITUATION. BE ESPECIALLY CAREFUL
TO KEEP THE ARM FROM FALLING WHEN A HEAVY TOOL IS
ATTACHED TO THE ARM TIP.
Type No .
SHF-20-50
S71(JIS)
Rubber wire diameter 1.50mm x Ring inner diameter 49.00mm KN3-M2143-000
Rubber wire diameter 0.99mm x Ring inner diameter 53.28mm KN3-M2144-000 Supplied with harmonic drive
5-11
CHAPTER 5 Periodic Inspection
Replacement parts
OMRON Parts No.
KN3-M2110-001
KN3-M2159-000
Note
Top of harmonic drive
For motor

Advertisement

Table of Contents
loading

Table of Contents