Omron SCARA R6Y-XC Series User Manual page 161

Table of Contents

Advertisement

2. Y-axis
1) Prepare the following tools and items.
• Harmonic grease 4B No.2
• Waste cloth (rag)
• Phillips-head screwdriver
• Hex wrench set
• Screw Lock (thread sealant)
• Torque-limiting wrench
• Replacement parts (See table below.)
Parts name
Harmonic drive
Rubber wire diameter 1.78mm x Ring inner diameter 72.75mm KN4-M257K-000
Rubber wire diameter 1.50mm x Ring inner diameter 49.00mm KN3-M2143-000
O-ring
Rubber wire diameter 0.99mm x Ring inner diameter 53.28mm KN3-M2144-000
2) Turn off the controller.
3) Place a sign indicating that the robot is being inspected, to keep others from
operating the controller switch.
4) Enter the safeguard enclosure.
5) Remove the Y-axis arm upper cover. Place the cover on the robot base
(pedestal) side with the machine harness still connected. Refer to "7 Remov-
ing the Robot Covers" in Chapter 4 for removing the covers.
6) Disconnect the connectors on the Y-axis motor power cable YM and
resolver cable YP.
7) Remove the Y-axis motor installation bolts (M5×14L, 4 pieces) and then
remove the Y-axis motor by swaying it gently right and left.(See Fig. 5-23.)
CAUTION
AN O-RING IS FITTED TO THE MOTOR, SO BE CAREFUL NOT TO LET IT
DROP INTO THE PERIPHERAL UNIT.
Replacement parts
Type No .
SHF-20-80
M5×14
Fig. 5-23
5-33
CHAPTER 5 Periodic Inspection
OMRON Parts No.
Note
KN4-M2510-001
Lower part of harmonic drive
For motor
Supplied with harmonic drive

Advertisement

Table of Contents
loading

Table of Contents