2. Y-axis
1) Prepare the following tools and items.
• Harmonic grease 4B No.2
• Waste cloth (rag)
• Phillips-head screwdriver
• Hex wrench set
• Screw Lock (thread sealant)
• Torque-limiting wrench
• Replacement parts (See table below.)
Parts name
Harmonic drive
Rubber wire diameter 1.00mm x Ring inner diameter 29.50mm
O-ring
Rubber wire diameter 0.80mm x Ring inner diameter 45.40mm
2) Turn off the controller.
3) Place a sign indicating that the robot is being inspected, to keep others from
operating the controller switch.
4) Enter the safeguard enclosure.
5) Remove the Y-axis arm upper cover. Place the cover on the robot base
(pedestal) side with the machine harness still connected.
Refer to "7 Removing the Robot Covers" in Chapter 4 for removing the
covers.
WARNING
WHEN YOU REMOVE THE Y-AXIS ARM INSTALLATION BOLTS (M3×20L,
8 PIECES) IN THE NEXT STEP, THE Y-AXIS ARM MAY COME OFF
CAUSING A HAZARDOUS SITUATION. BE ESPECIALLY CAREFUL TO
KEEP THE ARM FROM FALLING WHEN A HEAVY TOOL IS ATTACHED
TO THE ARM TIP..
Replacement parts
Type No.
SHF-17-50
KN3-M2510-001
S63(JIS)
KN3-M2519-000
KN3-M257K-000
KN3-M257L-000
5-17
CHAPTER 5 Periodic Inspection
OMRON Parts No.
Lower part of harmonic drive
For motor
Supplied with harmonic drive
Note