Body Ventilation system (12.01)
Climate Control (12.00)
Airflow Mode Actuator
Inspection
1. Connect the battery positive voltage to the Airflow
Mode Actuator terminal 6 (or 7), and ground to terminal
7 (or 6). Verify that the Airflow Mode Actuator operates
as shown.
If the operation condition is not normal, replace the Airflow
Mode Actuator.
Terminal
Airflow Mode Actuator operation
6
7
B+
Ground Defroster - Vent
Ground B+
Vent - Defroster
2. Verify that the resistance between terminals 1 and 5,
and 3 and 5 matches the Airflow Mode Actuator
operation as shown in the graph below.
If the operation condition and resistance are not normal,
replace the Airflow Mode Actuator.
12-1-4
KILOHM
4.7
1.2
Workshop Manual
VENT
90°
C0413
7
6
5
*
32°
DEFROSTER
DEFROSTER
VENT
3
5
1
6
7
BETWEEN 3-5
BETWEEN 1-5
TERMINALS WIRE
TERMINALS WIRE
VENT
VENT
DEFROSTER
AIRFLOW MODE ACTUATOR POSITION
3
1
*
DEFROSTER
October 2005