Engine Cranking System (03.06); Starting System; Maintenance; Starter Motor-Renew - Aston Martin V8 Vantage Workshop Manual

Table of Contents

Advertisement

Engine (03.00)

Engine Cranking System (03.06)

Starting System

Maintenance

Starter Motor-Renew

Repair Operation Time (ROT)
Item
Starter motor-Renew
Removal
1. Remove RH exhaust manifold (see Workshop Manual
procedure 09.00.CA Manifold - Exhaust - RH - Renew).
2. Switch battery isolation switch 'OFF'.
3. Remove battery cable from starter motor.
4. Disconnect solenoid multiplug from starter motor (see
Fig. 1).
5. Remove starter motor bolts (x2) (see Fig. 2).
Installation
1. Install starter motor bolts (x2).
2. Connect solenoid multiplug to starter motor.
3. Install battery cable from starter motor.
October 2005
Code
03.06.AB
Fig. 1
Fig. 2
Workshop Manual

Engine Cranking System (03.06)

4. Switch battery isolation switch 'ON'.
5. Install RH exhaust manifold (see Workshop Manual
procedure 09.00.CA Manifold - Exhaust - RH - Renew).

Starter Button-Renew

Repair Operation Time (ROT)
Item
Starter Button-Renew
Removal
1. Remove veneer panel using special tool to hook into
either one of two centre air flow vents
2. Disconnect starter button multiplug, squeeze the
retaining clips and remove button forward through
veneer panel
Installation
1. Align engine starter button switch and push into veneer
panel.
2. Reconnect multiplug.
3. Reposition veneer panel and press into place.
Code
03.06.AC
3-7-1