WAGO 852-1305 Manual page 303

8/4-port 100base-t/1000base-sx/lx industrial-managed-switch, 8 ports 100base-t,4 slots 1000base-sx/lx
Table of Contents

Advertisement

WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
Table 161: MODBUS Registers
Register
Address
0x0904
0x0905
0x0906
0x0907
0x0908
0x0909
0x090a
0x090b
0x090c
0x090d
0x090e
0x090f
0x0920
0x0940
0x0960
0x0980
0x09a0
0x09c0
0x09e0
0x0a00
0x0a20
0x0a40
0x0a60
0x0a80
0x0aa0
Manual
1.1.0
Data
Rep.
Description
Type
1 word
Hex
Port 1 status
High byte –Port No.
Low byte –Port Status.
b'0:1 Type
00: Bound(STP)
01: Bound(RSTP)
10: Bound(MSTP)
11: Internal(MSTP)
b'2 P2P
0: non P2P
1: P2P
b'3:4 State
00: Blocking
01: Learning
10: Forwarding
b'5:7 Role
000: Master
001:Alternate
010: Root
011: Designated
100: Backup
101: Disabled
110: Boundary
111: Unknown
1 word
Hex
Port 2 status
1 word
Hex
Port 3 status
1 word
Hex
Port 4 status
1 word
Hex
Port 5 status
1 word
Hex
Port 6 status
1 word
Hex
Port 7 status
1 word
Hex
Port 8 status
1 word
Hex
Port 9 status
1 word
Hex
Port 10 status
1 word
Hex
Port 11 status
1 word
Hex
Port 12 status
1 word
Hex
Instance ID (Fixed 0x01, 1)
1 word
Hex
Instance ID (Fixed 0x02, 2)
1 word
Hex
Instance ID (Fixed 0x03, 3)
1 word
Hex
Instance ID (Fixed 0x04, 4)
1 word
Hex
Instance ID (Fixed 0x05, 5)
1 word
Hex
Instance ID (Fixed 0x06, 6)
1 word
Hex
Instance ID (Fixed 0x07, 7)
1 word
Hex
Instance ID (Fixed 0x08, 8)
1 word
Hex
Instance ID (Fixed 0x09, 9)
1 word
Hex
Instance ID (Fixed 0x0a, 10)
1 word
Hex
Instance ID (Fixed 0x0b, 11)
1 word
Hex
Instance ID (Fixed 0x0c, 12)
1 word
Hex
Instance ID (Fixed 0x0d, 13)
Appendix