WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
9.2.2.4
Refusal MAC Settings
Additional Information
Please refer to the section "Function Description" for more information on
"Refusal MAC Settings".
Maximum number of MAC blacklist entries
Up to 20 entries can be configured.
Figure 35: WBM Page, "MAC Management" – "Refusal MAC Settings" Tab
Table 38: WBM Page, "MAC Management" – "Refusal MAC Settings" Tab
Refusal MAC Settings
Parameters
MAC Address
VLAN ID
Refusal MAC Settings
Parameters
MAC Address
VLAN ID
Action
Total counts
Manual
1.1.0
Configuring in the Web-Based Management System (WBM)
Default
Description
Enter the MAC address of a computer or device that
you want to reject.
The valid format is: hh:hh:hh:hh:hh:hh.
The switch receives any VLAN ID.
Any
Vlan
Enter the VLAN ID that you want to assign to the
computer or device.
Default
Description
This column displays the MAC addresses.
This field displays the VLAN ID of the MAC
address entry.
Click [Delete], to delete a MAC address entry
manually entered from the blacklist table.
This field displays the total number of entries in the
blacklist table.
131