Mains Fuses - Lenze 4800 Manual

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
13.1.1

Mains fuses

Stop!
An additional cable protection is required when using fuses of the operating class
aR (partial characteristic) as phase fuses.
If the fuses of the operating class gR also protect the cable, the cable cross-
sections must be dimensioned according to the fuse. Otherwise, provide a
separate cable protection!
Type
Fuse type
4902
FF 32 A
4903
FF 40 A
4904
FF 80 A
4905
FF 200 A
4906
FF 250 A
4907
FF 350 A
4X08
FF 450 A
4X09
FF 700 A
TAB 1
Type
Fuse type
4902
FF 20 A
4903
FF 32 A
4904
FF 63 A
4905
FF 125 A
4906
FF 200 A
4907
FF 315 A
4X08
FF 400 A
4X09
FF 550 A
TAB 2
The controllers 4X11 to 4X13 are equipped with cell fuses (F1.1/F1.2, F2.1/F2.2,
F3.1/F3.2). Fuseholders are not necessary.
Max. perm. size of the phase fuse (F'1, F'2, F'3)
Mains voltage
Operating class
(22 x 58)
(22 x 58)
(22 x 58)
(01.110)
(01.110)
(01.110)
(01.110)
(02.110)
Assignment of max. mains fuse size to the controller
Recommended phase fuse size (F'1, F'2, F'3) when I
controller
controller
Mains voltage
Operating class
(14 x 51)
(14 x 51)
(22 x 58)
(00.80)
(00.80)
(00.80)
(01.110)
(01.110)
Assignment of mains fuses to the controller when I
$
550V +0%
Order designation
gR
EFSFF0320AYI
gR
EFSFF0400AYI
gR
EFSFF0800AYI
aR
EFSFF2000AYR
aR
EFSFF2500AYR
aR
EFSFF3500AYR
aR
EFSFF4500AXP
aR
EFSFF7000AYR
= I
Amax
Arated
$
460V +0%
Order designation
aR
EFSFF0200AYH
aR
EFSFF0320AYH
aR
EFSFF0630AYI
aR
EFSFF1250AXL
aR
EFSFF2000AXL
aR
EFSFF3150AXL
aR
EFSFF4000AXR
aR
EFSFF5500AXP
= I
Amax
Arated
Accessories
Fuse holder
Order designation
EFH30006
EFH30006
EFH30006
EFH10003
EFH10003
EFH10003
EFH10003
EFH10003
of the
Fuse holder
Order designation
EFH10002
EFH10002
EFH30006
EFZ0003
EFZ0003
EFZ0003
EFH10003
EFH10003
$
and a mains voltage of
460V +0%
48XX/49XXSHB0399
13-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900

Table of Contents