Dt1 Element - Lenze 4800 Manual

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
7.5.11

DT1 element

Purpose
The DT1 element is to differentiate signals.
It can, for instance, be used for acceleration compensation (dv/dt).
Parameter setting
FIG 7-45
1. Input
With the function "freely assignable analog inputs" each input can be assigned to
a "terminal signal" from the table in C145.
2. Outputs
With the function "freely assignable analog inputs" the outputs can be assigned to
the targets listed under C146. The same signal is assigned to both outputs. The
output signal is limited to max. –200%.
3. Function
The gain K is set under code C650, the delay time Tv is set under C651. The input
sensitivity of the DT1 element can be reduced under C653, i.e. according to the
settings, only the high-value bits indicated are evaluated.
FIG 7-46
Code
Code
Name
Name
C650*
Gain
C651*
Time
constant
C652*
Input
C653*
Input
sensitivity
C 6 5 3
C 6 5 2
C 1 4 6 / C 1 4 7
I n p u t
1st order derivative element (DT1 element)
K
T v
Transfer characteristic of the DT1 element
Possible settings
Lenze Selection
1.00
-10.00
{0.01}
1.0 s 0.01 s
{0.01 s}
1.0 s
{0.1 s}
0 %
-100.0 %
{0.1 %}
-200 %
{1 %}
-1-
15 bit evaluation
-2-
14 bit evaluation
-3-
13 bit evaluation
-4-
12 bit evaluation
-5-
11 bit evaluation
-6-
10 bit evaluation
-7-
9 bit evaluation
C 6 5 0
C 6 5 1
± 2 0 0 %
C 1 4 5 / C 1 4 6
C 1 4 5 / C 1 4 6
t
Info
+ 10.00
1.00 s
5.0 s
100.0 %
Display parameter only
+200 %
Configuration
O u t p u t 1
O u t p u t 2
4900Str072
4900Str073
48XX/49XXSHB0399
7-85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900