C191*¤ Arithmetic
block 2
C338*
Input 1,
Arithmetic
block 2
C339*
Input 2,
Arithmetic
block 2
Code
Code
Name
Name
C600*¤ Arithmetic
block 3
C601*
Input 1,
arithmetic
block 3
C602*
Input 2,
arithmetic
block 3
7-72
48XX/49XXSHB0399
Arithmetic block 2
Possible settings
Lenze Selection
1
-0-
Output = C338
-1-
Output = C338 + C339
-2-
Output = C338 - C339
Output = C338 ¼ C339
-3-
-4-
Output = C338 / |C339|
-5-
Output = C338 / (100% - C339)
0%
-100.0 %
{0.1 %}
-200 %
{1 %}
0%
-100.0 %
{0.1 %}
-200 %
{1 %}
Arithmetic block 3
Possible settings
Lenze Selection
1
-0-
Output = C601
-1-
Output = C601 + C602
-2-
Output = C601 - C602
Output = C601 ¼ C602
-3-
-4-
Output = C601 / |C602|
-5-
Output = C601 / (100% - C602)
0%
-100.0 %
{0.1 %}
-200 %
{1 %}
0%
-100.0 %
{0.1 %}
-200 %
{1%}
Info
100.0 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
+200 %
only.
100.0 %
If an analog signal source (C145 / C146) is
assigned, the parameter will be displayed
+200 %
only.
Info
100.0 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
+200 %
only.
100.0 %
If an analog signal source (C145 / C146) is
assigned, the parameter will be displayed
+200 %
only.