Lenze 4800 Manual page 127

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
7-36
48XX/49XXSHB0399
Adaptation of the signal at the digital frequency output X8
If another signal than stated in the basic configuration (C005) is assigned, the
output frequency is adjusted via code C108.
Configurat
Basic assignment Adaptation of the output
ion
C005
-10-, -40-
n
from C382
act
-11-, -41-
n
from C382
act
-12-, -42-
n
from C051
act
-13-, -43-
n
from C051
act
-5x-
n
from C050
set
-6x-
n
from C050
set
-72-
n
from C050
set
The sign "-" means that a change does not influence the output frequency.
frequency with ...
C026 if
C030
C108
C025 = -13-
-
-
active
-
-
active
Selection
-
-
possible
-
-
-
-
Selection
-
possible
-
-
-
-
Selection
-
possible
Notes
The rotor zero position, which depends on
the resolver, is output on the zero track.
The encoder constant is only by the
incremental encoder used (hardware). A
zero track is only output if it is provided by
the incremental encoder.
The output signal is normalized to the
number of pulses of the incremental
encoder. A zero track will not be output.
At the output X8 the signal from X9 is
directly output (electrically buffered). A zero
track is only output, if it is connected to
input X9.
The output signal is normalized to the
number of pulses of the incremental
encoder. The corresponding encoder
constant can only be set under C030. The
gain can be set via C027 and C028 of the
input X5 (C025 = -10-). A zero track will
not be output.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900

Table of Contents