Lenze 4800 Manual page 217

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Code
Code
Name
Name
C067
Fault indication:
TRIP
C068
Operating state
7-126
48XX/49XXSHB0399
Possible settings
Lenze
Selection
Display
Meaning
---
no fault at present
ACI
armature circuit break
CCr
System fault
CE0
communication error (automation interface)
CE9
communication error (serial interface)
dEr
motor blocked or field break
EEr
external TRIP (from terminal)
FCI
break excitation circuit
LF
mains frequency fault f
LU
Undervoltage
LU1
LU1
fa lty phase mains break
faulty phase, mains break
OC5
I¼t overload (controller protection)
¼t overload (motor protection)
2
OC6
I
OF
mains frequency fault f
OH
overtemperature heat sink
OUE
mains overvoltage
P03
following error (tolerance exceeded)
P13
angle overrun
(angle difference cannot be compensated any
longer)
PER
software error
(please contact Lenze)
PR
PR
all parameters reset (factory setting)
all parameters reset (factory setting)
PR1
parameter set 1 reset (factory setting)
PR2
parameter set 2 reset (factory setting)
PR3
parameter set 3 reset (factory setting)
PR4
parameter set 4 reset (factory setting)
Sd1
short circuit or interruption of tacho
Sd2
open circuit of resolver
Sd3
encoder fault at X5
Sd4
encoder fault at X9
Sd5
master current < 2 mA with C034 = -1-
SP
wrong signal source polarity
–15V supply voltage is missing
U15
Bit
Meaning
0-3
Operation error (bit-decoded)
4-7
Communication error (bit-coded)
8
Controller enable
9
n
= 0
act
10
Setpoint inversion
11
Pulse inhibit
12
Quick stop
13
I
limit reached
max
14
n
= n
act
set
15
TRIP fault message
Info
When a TRIP occurs:
1.The display changes to C067.
2.TRIP blinks until the fault and the
memory are reset.
Reset memory:
with SH+PRG or via the input
TRIP-Reset, with LECOM via C043 or via
the input TRIP-Reset
3.TRIP is entered into the history buffer of
C067.
< 47Hz
mains
The last 8 entries can be displayed by
pressing
is displayed first. The history buffer isn't
is displa ed first The histor b ffer isn't
cleared when the mains switched on.
> 63Hz
After PR-TRIP , the code C180 must be
mains
reset to 2Q operation for controllers 48XX
or for 2Q applications.
16 bit status information
Only readable via LECOM. The signals are
described in the Lecom-A/B protocol.
and
. The TRIP saved last

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900