48XX/49XXSHB0399
Generic standards considered for the test of noise emission:
Basic standard
Test
EN 61000-4-2
3/95 Electrostatic discharge on housing and heatsink
IEC 1000-4-3
2/95 Electromagnetic fields
Frequency range 26-1000MHz
ENV 50140
8/93 High-frequency field
Frequency range 80-1000MHz,
80% amplitude modulated
Fixed frequency
900MHz with 200Hz, 100 % modulated
EN 61000-4-4
3/95 Fast transients,
burst on power terminals
Burst on bus and control cables
EN 61000-4-5
10/94 Surge test
Mains cable
Hameln, 01/03/1999
(i. V. Schäfer)
Product Manager
Limit value
Severity 3
6kV for contact,
8kV clearance
Severity 3
10V/m
Severity 3
10V/m
10V/m
Severity 3
2kV/5kHz
Severity 4
2kV/5kHz
Installation class 3
(i. A. Tolksdorf)
Commissioned for CE