Lenze 4800 Manual page 54

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Installation
Terminal
60
61
62
63
4-16
48XX/49XXSHB0399
Analog outputs (monitor outputs)
Switch position
S2
A
1
S2
S1
A
1
S1
1)
For changing the factory setting of switch S4, jumper 5 to ON (actual value with
ground reference), observe the following:
- Bridge terminals 4 and 5 externally.
- Set DIP switch S4, jumper 1-4 (preselected actual value) to double tacho
voltage.
The max. possible tacho voltage is 90 V!
Use
Internal ground, GND
Actual current value
Monitor 1
Output voltage(factory setting)
Monitor 1
Output current
Monitor 2
Output voltage(factory setting)
Monitor 2
Output current
Level
Resolution
-5 V...+ 5 V
correspond to the
rated current of the
controller
-10V...10V
11 bit
-20mA...+ 20mA
11 bit
-10V...+ 10V
11 bit
-20mA...+ 20mA
11 bit