Code
Name
C310* Speed-dependent
current limitation
Limit value 1
C311* Speed-dependent
current limitation
Limit value 2
C312* n0
Speed-dependent
current limitation
C313* n1
Speed-dependent
current limitation
C314* n2
Speed-dependent
current limitation
7-92
48XX/49XXSHB0399
Possible settings
Lenze Selection
100% 0.0 %
100% 0.0 %
3000
0 rpm
rpm
4000
0 rpm
rpm
5000
0 rpm
rpm
For more detailed information see the motor catalogue or contact the
manufacturer.
Info
{0.1 %}
+100.0 %
Valid for speed under C313
must be higher than C311!
{0.1 %}
+100.0 %
Valid for speed under C314
must be smaller than C310!
{1 rpm}
5000 rpm
Actual speed threshold (activation of
current limitation), condition: n
{1 rpm}
5000 rpm
Actual speed threshold for limit value 1,
condition: n
{1 rpm}
5000 rpm
Actual speed threshold for limit value 2,
condition: n
C310
C311
> n
1
0
> n
> n
2
1
0
> n
> n
2
1
0