Lenze 4800 Manual page 304

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Selection aid
15-12
48XX/49XXSHB0399
Parameter setting
Code
Input
Input according to motor nameplate
C083
xxx A
C084
xxx ms
C088
xxx A
C090
xxx V
Freely assignable analog inputs
C145
-4-
C146
-15-
C145
-3-
C146
-16-
C145
-10-
C146
-1-
C145
-9-
C146
-3-
C145
-1-
C146
-7-
Freely assignable digital inputs
C112
-3-
C113
-32-
C112
-5-
C113
-31-
Arithmetic block
C191
-4-
@
Convert distance
diameter
C025
-3-
C026
C027
2.000
Adjustment of speed controller
C011
xxxx rpm
C025
-2-
C029
n
act
process controller
C330
xxx %
C331
xxx %
Application parameters
C022, C023
xxx A
C019
xxxx rpm
C070
V
pn
C222
V
pp
Save parameter
C003
Description
Rated field current
Armature-time constant
Rated motor current
Rated motor voltage
Input selection term. 8
Arithmetic block2 input 1
Input selection term. 6
Arithmetic block2 input 2
Input selection arithmetic block output
Main set-value C046
Input selection process controller output
Additional set-value C049
Input selection term. 1.2
Actual process controller value
Input selection E3
Process controller evaluation
Input selection E5
Process controller I component off
Output = input 1 / input 2
Input selection term. 6
Offset for distance a = -xxx mV
Evaluation for diameter
Enter max. speed
Select adjustment at terminals 3 and 4
Adjust speed
Select position set-value
Evaluation of process controller output
Maximum motor current
Set threshold n
= 0
act
At high inertias, adapt n - controller gain
Optimise process controller
Save parameter set