Feedback Systems - Lenze 4800 Manual

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
4.3.5

Feedback systems

Several feedback systems can be connected to the controller and configured:
( Armature voltage control
( DC tacho feedback
( Resolver feedback
( Encoder feedback
DC tacho feedback
Tacho signals are connected via term. 3/4 of terminal block X1. The controller
processes rated tacho voltages of 10...180V (chapter 4.3.5.1).
Resolver feedback (X7)
( 2-pole resolver (V = 10 V, f = 5 kHz)
( Connection to a 9-pole Sub D socket X7
( Resolver cable and resolver are monitored for wire breakage (fault message
FIG 4-15
Pin assignment of socket X7:
Pin
Signal
Cross section
- Incremental encoder TTL
- Incremental encoder HTL
- We recommend to use the pre-cut Lenze system cable
(see chapter 13.3).
"Sd2")
Resolver connection (9-pole Sub D socket)
1
2
+ REF
-REF
0.5
X7
l max = 50 m
+REF
-REF
+COS
-COS
+SIN
-SIN
3
4
5
6
GND
+COS
-COS
+SIN
0.14
Installation
1
2
3
4
5
6
7
8
9
4900Str015
7
8
9
-SIN
---
---
48XX/49XXSHB0399