Torque Control With Speed Limitation - Lenze 4800 Manual

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Code
Code
Name
Name
[C005*] Configuration
C009*¤ Controller
address
7-120
48XX/49XXSHB0399
Possible settings
Lenze
Selection
11
Speed control with additional setpoint
-10-
Armature voltage control
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, 1/2.
limit
-11-
Act. value encoder: tacho at X1/3,X1/4
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
limit
-12-
Act. value encoder: resolver at X7
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
limit
-13-
Act. value encoder: increment. encoder at X9
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
limit
Torque control with speed limitation and addi-
tional setpoint
-40-
Armature voltage control
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, 1/2.
set
-41-
Act. value encoder: tacho at X1/3, X1/4
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, 1/2.
set
-42-
Act. value encoder: resolver at X7
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
set
-43-
Act. value encoder: increment. encoder at X9
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
set
Dig. freq. of master with additional setpoint
-52-
Act. value encoder: resolver at X7
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
limit
-53-
Act. value encoder: increment. encoder at X5
n
: analog at X1/8
set
n
: analog at X1/6
add
M
: analog at X1/1, X1/2
limit
Digital frequency bus
-62-
Act. value encoder: resolver at X7
n
: digital at X9
set
M
: analog at X1/1, X1/2
limit
-63-
Act. value encoder: increment. encoder at X5
n
: digital at X9
set
M
: analog at X1/1, X1/2
limit
Digital frequency cascade
-72-
Acutal value encoder: resolver at X7
n
: digital, X5
set
M
: analog at X1/1, X1/2
limit
1
1
{1}
Info
If C005 = -10- or -40-, field control
override is not possible.
A change of the configuration changes the
control structure and the terminal
assignment and activates important
monitoring functions.
Change monitoring functions:
C119 / C120
Change terminal signals: C145 / C146.
99
Bus participant number for operation via
interface: Parameter 10 reserved for
broadcasting to groups of participants.
Can only be changed with C001 = -0-
and -1-.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900

Table of Contents