Lenze 4800 Manual page 33

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
( Controllers 4808 to 4813 (2Q controllers)
Output power
1)
Mains voltage
Armature voltage
Rated armature current
(continuous operation)
Maximum current
(short-time operation)
Field voltage
2)
Max. field current,
controlled
Power loss
3)
Ambient temperature in
operation
Weight approx.
1)
referred to a mains voltage of 3
2)
The field is controlled as a current source, i.e. the field voltage depends on the field resistance.
3)
at rated armature current
$
4)
T
35°C: no power derating
amb
Type
4808
Order No.
EVD 4808-E
P
[kW]
152
el
V
mains
V
A
I
[A]
330
Arated
I
[A]
400
Amax
V
F
I
[A]
15
F
P
[W]
830
loss
T
[•C]
amb
[kg]
28
¼
~
400V
$
,
35°C
T
45°C: power derating 1%/K
amb
Technical Data
4809
4811
EVD 4809-E
EVD 4811-E
230
322
3 ô 340...460 V~ á0%, 50...60Hz
= 400 V (1.15 ¼ V
460 V if V
mains
500
700
600
840
= 0.875 ¼ V
V
Fmax
L1-L3
30
1220
2100
0...+ 35
4)
28
60
4812
4813
EVD 4812-E
EVD 4813
460
552
)
mains
1000
1200
1200
1350
2850
3400
60
60
48XX/49XXSHB0399
3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4900

Table of Contents