Configuration
Code
Code
Name
Name
C257*
Speed trimming
C260*
Upper motor
potentiometer
limit
C261*
Lower motor
potentiometer
limit
C262*
Motor pot.
acceleration
time
C263*
Motor pot.
deceleration
time
C264*¤ Motor
potentiometer
deactivation
function
C265*¤ Initialisation
function
Sample & Hold
C266*
Motor pot.:
Operation via
keypad
C267*¤ Sample and
Hold function
C270*
Analog/
digital
conversion 1
C271*
Analog/ digital
conversion 2
C272*
Digital/
analog
conversion 1
7-138
48XX/49XXSHB0399
Possible settings
Lenze
Selection
0 rpm -5000 rpm
{1}
100% -100.0 %
{0.1 %}
0 %
-100.0 %
{0.1%}
10 s
1 s
{1 s}
10 s
1 s
{1 s}
0
-0-
No function, motor potentiometer is not
changed.
-1-
Down to 0%, motor potentiometer output
runs with the corresponding acceleration or
deceleration time to 0%.
-2-
Down to lowest limit, motor potentiometer
output runs with the corresponding
acceleration or deceleration time to the value
under C261.
-3-
Jump to 0%, motor potentiometer output
immediately changes to 0%.
-4-
Jump to the lowest level, motor
potentiometer immediately changes to the
value indicated under C261.
-5-
Up to the highest level, motor potentiometer
output runs with the corresponding
acceleration or deceleration to the value
indicated under C260.
0
-0-
Acceptance of the saved value S&H output
accepts the value which was set before
switching the mains.
-1-
Lower limit, S&H output accepts the value of
C261.
100.0 %
{0.1 %}
0
-0-
S&H for motor potentiometer output
-1-
S&H for FAI signal
-16384
{1}
-16384
{1}
-16384
{1}
Info
+5000 rpm
Fixed speed offset with digital frequency
configurations (C005 = -5X-, -6X- and
-72-). If an analog signal source
(C145/C146) is assigned, the parameter
will be displayed only.
+100.0 %
C260 must be higher than C261!
+100.0 %
C261 must be smaller than C260!
5000 s
C262 is activated if the motor
potentiometer terminal is set to "UP"
Reference: Change of 0...–100%
5000 s
C263 is activated if the motor
potentiometer terminal is set to "DOWN"
Reference: Change of 0...–100%
Function which is executed when
deactivating the motor potentiometer
(terminal DEACTIVE is set).
Function which is executed when
switching on the mains.
+100.0 %
Under C266, the motor potentiometer can
also be operated with
Display: Output value of the motor
potentiometer in % and exact value of
control program.
16384
Display: Value assigned and digitized via
C145 / C146
Output only via interfaces
16384
Display: Value assigned and digitized via
C145 / C146
Output only via interfaces
16384
Input: Value for the conversion into an
analog signal is to be entered via the
monitor outputs X4/62, X4/63 or digital
frequency output X8.
Input only via interfaces.