Lenze 4800 Manual page 214

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Code
Code
Name
Name
C029¤
Automatic
adjustment for
C025
C030¤
Constant for the
digital frequency
output
C032*
Ratio numerator 0.1000 -3.2767 {0.0001}
C033*
Ratio
denominator
C034*¤ Master current
C038¤
Input selection:
JOG setpoint
C039
JOG speed for
C038
C040
Controller
enable
C041¤
CW/CCW
direction of
rotation
C042¤
Quick stop
Possible settings
Lenze
Selection
C025 = -10-, -11-:
Adjustment of the digital frequency inputs X5, X9
-100.0%
{0.1%}
C025 = -12-
Adjustment of the resolver
-100.0%
{0.1%}
1
-0-
8192 increments / revolution
-1-
4096 increments / revolution
-2-
2048 increments / revolution
-3-
1024 increments / revolution
-4-
512 increments / revolution
-5-
256 increments / revolution
3.2767
0.1000 0.0001
{0.0001}
0
-0-
i
= -20 mA ... + 20 mA
master
-1-
I i
|= 4 mA ... 20mA
master
1
-1-
Selection JOG1
-2-
Selection JOG2
...
-15-
Selection JOG15
-100.0 % n
{0.1 %}
max
100.0%
JOG1
75.0%
JOG2
50.0%
JOG3
25.0%
JOG4
0.0%
JOG5
..
...
0.0%
JOG15
-0-
Controller inhibited
-1-
Controller enabled
-0-
Main setpoint not inverted
-1-
Main setpoint inverted
-0-
No quick stop
(corresponds to X2/21 or X2/22 = HIGH)
-1-
Quick stop active
(corresponds to X2/21 and X2/22 = LOW)
Drives decelerates to standstill following the
quick-stop ramp C105.
Configuration
Info
Automatic adjustment only possible, if X5
or X9 are not selected as acutal speed
inputs:
100.0%
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain
factor.
Automatic adjustment is only possible, if
the resolver is not used as a speed
feedback system:
100.0%
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain
factor.
Number of increments per revolution for
the digital frequency output
Ratio numerator for configurations with
digital frequency
If an analog signal source is assigned
(C145/146), only the parameter will be
displayed.
3.2767
Ratio denominator for configurations with
digital frequency
For master current input, the switch S3/1
must be set to ON.
C034 = -1-:
If i
< 2mA, the monitoring message
master
Sd5 will be displayed.
Select JOG setpoint to be set under C039.
+100.0 % n
Enable JOG setpoints via the digital inputs
max
or via C045.
Input only via LECOM1 or LECOM2. C183
indicates the source which has inhibited
the controller.
Input only with control via keypad or
interface.
Display only with terminal control.
Input only with control via keypad or
interface.
Display only with terminal control.
48XX/49XXSHB0399