Lenze 4800 Manual page 226

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Code
Code
Name
Name
C148
Additional
torque value 1
C149
Additional
torque value 2
C151*
FDO
Status
[C180*] 4Q/2Q
operation
C182*
T
time of the
i
S-shape
ramp function
generators
C183
Origin of
controller inhibit
C185
Motor power
C186
Motor torque
C187
Field current
setpoint
C188
Actual field
current
C189
Mains
frequency
C190*¤ Arithmetic
block 1
C191*¤ Arithmetic
block 2
Possible settings
Lenze
Selection
0
-100.0 % M
{0.1%}
max
-200 % M
{1%}
max
0
-100.0 % M
{0.1%}
max
-200 % M
{1%}
max
Bit
Free digital output
0
FDO 1
...
11
FDO 12
12
Relay output
-0-
4Q operation (49XX)
-1-
2Q operation (48XX)
20.0 s 0.01 s
{0.01s}
1s
{0.1s}
10s
{1s}
Display
Origin of ctrl inhibit
Terminal or term.
Terminal
Keypad or kp
Keypad (STP key)
LECOM1 or L1
LECOM1 interface
Aut.int. (AIF)
Automation / fieldbus interface
(module, InterBus, PROFIBUS, ...)
oth. src. Other source
or o.s. Release: TRIP or message
Information: C065, C067
-500.0 kW
{0.1 kW}
-999 Nm
{1 Nm}
0.00 A
{0.01 A}
0.00 A
{0.01 A}
0.0 Hz
{0.1 Hz}
1
-0-
Output = C046
-1-
Output = C046 + C049
-2-
Output = C046 - C049
Output = C046 ¼ C049
-3-
-4-
Output = C046 / |C049|
-5-
Output = C046 / (100% - C049)
1
-0-
Output = C338
-1-
Output = C338 + C339
-2-
Output = C338 - C339
Output = C338 ¼ C339
-3-
-4-
Output = C338 / |C339|
-5-
Output = C338 / (100% - C339)
Configuration
Info
+100.0 % M
Display only with terminal control. If the
max
terminal control is deactivated, the actual
+200 % M
max
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M
correspond to 100 % I
max
C023)
+100.0 % M
Display only with terminal control. If the
max
terminal control is deactivated, the actual
+200 % M
max
terminal value will be accepted for
opera tion. Armature setting range: 100 %
M
correspond to 100 % I
max
(C022/C023)
C151 indicates the states of the digital
outputs as decimal or binary values. The
polarity reversal under C118 is not
considered.
Important for controller type 48XX:
Controllers must only be operated with
C180 = -1-!
Fault PR sets C180 = -0-. It is absolutely
necessary to set C180 = -1- before
commissioning.
1 s
T
time for the S-shape ramp function
i
generator of the main setpoint
10s
50s
Display: Source which has inhibited the
controller
500.0 kW
Display: actual motor power
999 Nm
Display: actual motor torque
50.0 A
Display: actual field current setpoint
50.0 A
Display: actual field current value
100.0 Hz
Display: actual mains frequency
(C022,
max
max
48XX/49XXSHB0399
7-135