Lenze 4800 Manual page 117

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Code
Name
C116*¤ Input
selection:
Freely
assignable
digital
output
[C117*] Function
for C116
[C118]
Polarity for
C116
C128*
Delay for
C116
7-26
48XX/49XXSHB0399
Possible settings
Lenze
Selection
1
-1-
FDO 1
-2-
FDO 2
...
-12-
FDO 12
-13-
Relay output X3/K11, X3/K14
-0-
No function
ˆ n
-1-
n
C017 (FDO1)
act
x
-2-
Controller enabled (FDO10)
-3-
n-controller output = M
-4-
Ready for operation (RDY) (FDO11)
-5-
Pulse inhibit (IMP) (FDO12)
-6-
TRIP (relay)
-7-
Warning (FDO6)
-8-
Message (FDO7)
-9-
Ramp function generator Input = Output
(FDO3)
-10-
n
= n
(FDO5)
act
set
-11-
n
= 0 (FDO4)
act
-12-
I
= 0 (FDO8)
A
-13-
I
& n
= 0 (FDO9)
A
act
C046 or C049 > n
-14-
-15-
|I
| > I
(Threshold C244)
A
x
-16-
I
> I
(Threshold C245)
F
x
-17-
|n
| > n
(Threshold C242)
act
x
-18-
Brake control
-19-
Comparator 1
-20-
Comparator 2
-0-
Output is HIGH active (FDO2, 3, 5)
-1-
Output is LOW active (FDO1, 4, relay)
0.000 s 0.000 s
{0.001 s}
Info
The digital outputs FDO1..FDO12 and the
relay output X3/K11, X3/K14 are freelay
assignable with the functions under C117.
Multiple assignment is possible.
The outputs FDO1...FDO5 are assigned to
the terminals X3/A1...X3/A5.
FDO6...FDO12 can only be accessed via
LECOM.
Assignment of functions:
1.Select output under C116.
2.Assign function under C117.
Only for FDO1...FDO5, relay output:
3.Determine polarity under C118.
4.Determine signal delay under C128.
(FDO2)
max
(Threshold C243)
x
240.000 s
Signal delay times for FDO 1...5 and relay
output.

Hide quick links: