Lenze 4800 Manual page 94

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Code
Code
Name
Name
C038¤
Input
preselection:
JOG
set-value
C039
JOG speed
for C038
Assignment of the digital inputs
The number of inputs to be assigned with the function "enable JOG set-value",
depends on the number of JOG set-values required.
This function can be assigned to up to four inputs.
For input assignment, observe the notes in chapter 5.6.
JOG set-value enabling with terminal control
The assigned digital inputs must be controlled according to the table below to
enable JOG set-values.
The input with the lowest figure is the first input, the input with the next higher figure
is the second input, and so on (e. g. E4 = 1. input, E5 = 2. input).
C045 indicates the active set-value.
Possible settings
Lenze Selection
1
-1-
Selection JOG1
-2-
Selection JOG2
...
-15-
Selection JOG15
-100 % n
{0.1 %}
max
100.0%
JOG1
75.0%
JOG2
50.0%
JOG3
25.0%
JOG4
0.0 %
JOG5
..
...
0.0 %
JOG15
Number of JOG set-values required
1
2...3
4...7
8...15
JOG 1
1
JOG 2
0
JOG 3
1
JOG 4
0
JOG 5
1
JOG 6
0
JOG 7
1
JOG 8
0
JOG 9
1
JOG 10
0
JOG 11
1
JOG 12
0
JOG 13
1
JOG 14
0
JOG 15
1
Configuration
Info
Select JOG setpoint to be set under C039.
+100.0 % n
Enable JOG set-values via the digital
max
inputs or via C045.
Number of inputs required
at least 1
at least 2
at least 3
2. input
3. input
0
0
1
0
1
0
0
1
0
1
1
1
1
1
0
0
0
0
1
0
1
0
0
1
0
1
1
1
1
1
4
4. input
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
48XX/49XXSHB0399