Technical data
Rated data

Operation at rated mains voltage 230 V

4.2.2
Operation at rated mains voltage 230 V
Basis of the data
Mains
1/N/PE AC
Type
E84AVxxx2512
E84AVxxx3712
E84AVxxx5512
E84AVxxx7512
E84AVxxx1122
E84AVxxx1522
E84AVxxx2222
Assignment
Type
E84AVxxx2512
E84AVxxx3712
E84AVxxx5512
E84AVxxx7512
E84AVxxx1122
E84AVxxx1522
E84AVxxx2222
30
efesotomasyon.com - Lenze
Voltage
U
[V]
LN
230
180 − 0 % ... 264 + 0 %
Mains current at I
aN
with external mains
without external
choke
mains choke
I
[A]
I
LN
3.0
4.2
5.0
7.0
9.9
11.4
16.4
l
Voltage range
U
[V]
LN
Output power
U, V, W
[A]
S
[kVA]
LN
aN
3.4
0.6
5.0
0.9
5.3
1.1
8.0
1.4
12.0
2.0
13.7
2.5
21.8
3.4
Mains choke
ELN1−0900H005
ELN1−0500H009
ELN1−0250H018
Frequency range
f [Hz]
45 − 0 % ... 65 + 0 %
Motor power
4 pol. ASM
P
[kW]
aN
0.25
0.37
0.55
0.75
1.1
1.5
2.2
EDS84ASC552 EN 6.0