Show/Hide Bookmarks
8.5
Checking the drive system
Note!
The measurements should be made with a digital voltmeter. The stated measuring
values are rated values. In the event of deviations, a defect has occured.
8.5.1
Checking the motor
Warning!
( The measurements described must only be carried out by specialists.
( Disconnect the motor from the mains.
( Tests should only be carried out when no voltage is applied!
Measurement
Armature resistance
Insulation resistance of the armature A earth potential
Field resistance
Insulation resistance of the field
Troubleshooting and fault elimination
Measuring point
A B at the controller
B earth potential
I K
I earth potential
K earth potential
Measured value
< 10 W
R
A
R
R
< 1kW
F
R
48XX/49XXSHB0399
8-7