Configuration
Code
Code
Name
Name
[C146*] Function
for C145
[C147*] Priority for
C145
7-32
48XX/49XXSHB0399
Possible settings
Lenze
Selection
-0-
No function
-1-
Main setpoint of C046
-2-
Input for torque selection
-3-
Additional setpoint of C049
-4-
V
of the speed controller
pn
-5-
Field current setpoint
-6-
Process controller: setpoint (C330)
-7-
Process controller: actual value
-8-
Process controller: evaluation (C331)
-9-
Process controller: ext. V
-10-
C027 of X5
-11-
C027 of X9
-12-
Gearbox factor (C032)
-13-
Angle trimming of C256
-14-
Speed trimming of C257
-15-
Arithmetic block 2 - input 1 (C338)
-16-
Arithmetic block 2 - input 2 (C339)
-17-
Fixed setpoint block input
-18-
Analog / digital conversion 1 (C270)
-19-
Analog / digital conversion 2 (C271)
-20-
Dead band element input (C622)
-21-
DT1 element input (C652)
-22-
Absolute value generator input (C660)
-23-
Limiting element input (C632)
-24-
PT1 element input (C641)
-25-
Arithmetic block 3 - input 1 (C601)
-26-
Arithmetic block 3 - input 2 (C602)
-27-
Addition block 1 - input 1 (C610)
-28-
Addition block 1 - input 2 (C611)
-29-
Addition block 1 - input 3 (C612)
-30-
Addition block 2 - input 1 (C614)
-31-
Addition block 2 - input 2 (C615)
-32-
Addition block 2 - input 3 (C616)
-33-
Additional torque setpoint 1 (C148)
-34-
Additional torque setpoint 2 (C149)
-35-
FAI input of the S&H module
-36-
AIF process controller: act. value
-37-
Limiting element 2 input (C637)
-38-
Comparator 1 input 1 (C580)
-39-
Comparator 1 input 2 (C581)
-40-
Comparator 2 input 1 (C590)
-41-
Comparator 2 input 2 (C591)
-42-
Input for ext. excitation characteristic
-43-
n
of C051 (for tacho feedback)
act
-44-
n
of C051 (for resolver or incremental
act
encoder feedback)
-46-
Digital frequency setpoint
-0-
Terminal function not active, if terminal control
is switched-off under C001.
-1-
Terminal function remains active, if terminal
control is switched-off under C001.
Info
If C146 = -4-, V
corresponds to 0% at the input V
C320 and –100% at the input V
C070.
If C146 = -5-, the field current setpoint
corresponds to –100% at the input of the
rated current under C083. The minimum
adjustable value is determined under
C231.
setting
p
C146 = -43-, -44-, -46- are for display
only (according to the configuration). They
cannot be assigned.
of the n-controller
pn
under
p2
under
pn