Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Code
Code
Name
Name
C580*
Input 1,
Comparator 1
C581*
Input 2,
Limit value
for
comparator 1
C582*
Hysteresis for
lower
threshold
Comparator 1
C583*¤ Memory
function
Comparator 1
C584*¤ Reset
function
Comparator 1
C590*
Input 1,
Comparator 2
C591*
Input 2,
Limit value
for
comparator 2
C592*
Hysteresis for
lower
threshold
Comparator 2
C593*¤ Memory
function
Comparator 2
C594*¤ Reset
function
Comparator 2
7-88
48XX/49XXSHB0399
Possible settings
Lenze Selection
0 % -100.0 %
{0.1 %}
-200 %
{1 %}
0 % -100.0 %
{0.1 %}
-200 %
{1 %}
0 % 0 %
{0.1 %}
-0-
Memory function not active
The output is reset when the value falls below
the lower threshold (C581 - C582)
-1-
Memory function active
The output remains set after initial switch on.
-0-
Reset function not active
-1-
Reset function active
0 % -100.0 %
{0.1 %}
-200 %
{1 %}
0 % -100.0 %
{0.1 %}
-200 %
{1 %}
0 % 0 %
{0.1 %}
-0-
Memory function not active
The output is reset when the value falls below
the lower threshold (C591 - C592)
-1-
Memory function active
The output remains set after initial switch on.
-0-
Reset function not active
-1-
Reset function active
Info
+100.0 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
+200 %
only.
+100.0 %
If an analog signal source (C145/C146) is
+200 %
assigned, the parameter will be displayed
only.
+100 %
Lower threshold = C581 - C582,
reference: C581
The activation resets the output
+100.0 %
If an analog signal source (C145/C146) is
+200 %
assigned, the parameter will be displayed
only.
+100.0 %
If an analog signal source (C145/C146) is
+200 %
assigned, the parameter will be displayed
only.
+100 %
Lower threshold = C591 - C592,
reference: C591
The activation resets the output