Show/Hide Bookmarks
3.2
General data / application conditions
Field
Type of protection
Permissible humidity
Temperature ranges
Influence of the installation height
Degree of pollution
Noise emission
Noise immunity
Values
IP20 to DIN 40050, steel sheet housing
Relative humidity 90%, no condensation
-25 C...+ 55 C
Storage
-25 C...+ 70 C
Transport
h $ 1000m : 100% rated armature current
h $ 2000m : 95% rated armature current
h $ 3000m : 90% rated armature current
h $ 4000m : 85% rated armature current
VDE 0110, part 2, degree of pollution 2
Controllers must not be exposed to a corrosive or explosive
atmo-sphere.
Requirements to EN 50081-2, IEC 22G
Limit-value class A (EN 55011; industrial premises) with RFI filter
Limit values maintained with RFI filter.
Requirements to EN 50082-2, IEC 22G
Requirements
ESD
RF interference
(enclosure)
Burst
Surge
Technical Data
Standard
Severity
EN 61000-4-2 3, i.e. 8kV air discharge
6 kV contact discharge
IEC 1000-4-3
3, i.e. 10 V/m
EN 61000-4-4 3/4, i.e. 2kV / 5kHz
EN 61000-4-5 3, i.e. 1.2 / 50 m
s
1kV phase - phase
2kV phase - PE
48XX/49XXSHB0399
3-3