Lenze 4800 Manual page 295

Dc speed controller
Table of Contents

Advertisement

Show/Hide Bookmarks
Parameter setting
Code
Input according to motor nameplate
C083
C084
C088
C090
Enter controller configuration
C000
C005
Input of current limits
C022, C023
Adjustment of speed controller
C011
C025
C232
C029
Application parameters
C070
Save parameter
C003
Note!
( With armature-voltage feedback, the control terminals are still volt-free!
( Mains disconnection only when no current is applied!
Input
Description
xxx A
Rated field current
xxx ms
Armature-time constant
xxx A
Rated motor current
xxx V
Rated motor voltage
-2-
Extended code set
-10-
Speed control with armature-voltage feedback
xxx A
Maximum motor current
xxxx rpm
Enter max. speed
-5-
Select armature voltage
xx % V
I
R - Set compensation
¼
Arated
n
Adjust speed
act
V
At high inertia, adapt n - controller gain V
pn
Save parameter set
Selection aid
pn
48XX/49XXSHB0399