Configuration
7.1.1.6
7-6
48XX/49XXSHB0399
Acceleration and deceleration times T
Each acceleration or deceleration time refers to a speed change from 0 to n
(C011). The times T
and T
ir
FIG 7-3
Calculation of acceleration and deceleration time
Here t
and t
correspond to the times desired for the change from n
ir
if
vice versa.
The times T
and T
calculated are setting values for the controller.
ir
if
( Acceleration and deceleration time C012 and C013
The ramp function generator of the main set-value (n
the times T
and T
under C012 and C013.
ir
if
( Additonal acceleration and deceleration times
Alternaltively to the acceleration and deceleration times under C012 and C013,
additional T
and T
times can be retrieved from the memory, for instance, to
ir
if
change the drive acceleration from a certain speed on.
Programming of additional acceleration and deceleration times
Set the additional T
times in two steps. The selection under C100 is valid for a pair
i
of acceleration and deceleration times:
( Select additional acceleration/deceleration times under C100.
( Enter the required acceleration time under C101, and the deceleration time
under C103.
For several additional T
i
A maximum of 15 additional acceleration and deceleration times can be
programmed.
to be set can be calculated as follows:
if
times repeat these two steps as often as required.
,T
ir
if
to n
1
or JOG set-value)is set via
set