DOOR LOCKS
Interlock switches are used to communicate the status of the oven door and the top cover to the printer. For
safety reasons, the oven door and top cover must be closed before the X, Y, and Z motors will operate.
GENERAL SAFETY PRACTICES
Abide by these general safety practices when working with this printer.
High Voltage: High voltage is present in the printer.
Warning: Only use an OSHA or CE approved step stool when accessing the
area under the top cover of the printer.
Warning: Always wear safety gloves and long sleeves when working inside the
oven. Components are hot.
ENVIRONMENTAL REQUIREMENTS
The F123 Series printer is for indoor use only.
•
Air quality conditions with excessive solid particulates (conductive or non-conductive) may
•
result in system damage.
•
Air quality conditions in which airborne oils are allowed to accumulate on or within the printer
can damage the plastic components.
System operating temperature shall be in the range of 59°F to 86°F (15°C to 30°C), with
•
relative humidity range of 30% to 70% non-condensing.
•
System storage temperature shall be in the range of 32°F to 95°F (0°C to 35°C), with relative
humidity range of 20% to 90% non-condensing.
•
Altitude shall not exceed 6561.68 feet (2000 m).
Material storage shall be in the range of 55°F to 86°F (13°C to 30°C), with relative humidity less
•
than 70%.
•
Noise emission (acoustic):
•
<32dBA when idle
•
<46dBA when building