Installing the Top Cover Interlock Sensor
1.
Use a 2 mm hex wrench to reinstall the mounting screws (2) that secure the interlock sensor to
the mounting bracket. See
2.
Reconnect the top cover sensor cable at the quick disconnect connector.
3.
Install three cable ties to secure the sensor cable to the mounting bracket.
4.
Use a 2.5 mm hex wrench to reinstall the mounting screws (2) that secure the interlock actuator
to the top cover. See
5.
Close the top cover.
6.
Power ON the printer.
7.
Verify operation by opening and closing the top cover.
8.
If the touchscreen displays errors indicating that the cover is not closed, adjust the position of the
actuator.