Use the Down button to enter the value obtained in
height. For example, if you measured an average of 0.0080 in. (0.2032 mm) for a tip with a slice
height of 0.010 in. (0.254 mm), press the Down button until 0.0080 (0.2032) is displayed within
the Slice Height field.
Figure 6-16:
Z Offset Adjustment
English units
•
Use the Up button to enter the value obtained in
height. For example, if you measured an average of 0.0120 in. (0.3048 mm) for a tip with a slice
height of 0.010 in. (0.254 mm), press the Up button until 0.0120 (0.3048) is displayed within the
Slice Height field.
Figure 6-17:
Z Offset Adjustment
English units
step C
Down button
for adjusting
Z offset
step C
Up button
for adjusting
Z offset
152
if this value is less than the tip's slice
Metric units
if this value is greater than the tip's slice
Metric units