Stratasys F170 User Manual page 157

F123 series shared office 3d printers
Table of Contents

Advertisement

Figure 6-11:
Calibration Part
Support toolpath is most centered between the alignment
indicators at the 4, indicating an adjustment of X1 = 0.004
Support
toolpath,
most
centered
at 4
C.
Within the Manual Tip Calibration page, slide all four of the scale icons on the screen to
match where the support toolpath is most centered between the alignment indicators. The
Delta X and Delta Y fields will change to reflect adjustments made.
Note: One offset value must be selected for each side (X1, X2, Y1 and Y2).
If the Delta X and the Delta Y values are both within the range of -0.002 to +0.002 in., the printer
is calibrated and an adjustment is not required. The following figure shows an XY offset within
tolerance, requiring no adjustments. Proceed to
Not
centered
at 0
Alignment
indicators
step
3.