Figure 190.
3.
To show the transmitters of a Dante device, click the
the
Dante Transmitters
+
The
4.
To show the receivers of a Dante device, click the
the
Dante Receivers
5.
Click the intersection of the desired subscription between a transmitter and a
receiver (
Example: The mic/line input transmitters of the
AXI22D-ConfRm2
A check mark at the intersection indicates the subscription is made. A check mark also
appears next to the receiver channel.
NOTE: A receiver can connect to only one transmitter. A transmitter can connect to
multiple receivers.
Disconnecting Inputs from Outputs
To undo routing, click the junction again to disconnect the receiver from the transmitter.
NOTE: After making changes to Dante network routing such as subscriptions, device
names, or channel labels, wait at least 5 seconds before disconnecting or powering
down the devices. This ensures that the new information is properly saved to those
devices. Device level configuration such as sample rates, latency, and clock settings
are saved instantly.
Routing Tab of Network View Screen
panel, such as
changes to a
sign when the device expands.
–
panel, such as
).
3
are routed to the EXP input receivers of the
+
box next to the desired device in
(see figure 190,
AXI22D-ConfRm1
+
box next to the desired device in
(
DMP128Plus-MainRack
2
AXI22D-ConfRm1
DMP128Plus-MainRack
DMP 128 Plus • Dante Controller
above).
1
).
and
.
120
Need help?
Do you have a question about the DMP 128 Plus and is the answer not in the manual?
Questions and answers